The Uninterruptible Power Systems (UPS) with an 800 VA line-interactive sine-wave design offers a reliable and efficient power backup solution for entry-level servers and IT equipment. Built in a tower/rack format, it provides flexibility in deployment, ensuring compatibility with various installation environments.
Specification
TECHNOLOGY Line-interactive FORMAT Convertible tower/rack (2U) Rated voltage 208 / 220 / 230 / 240 V Voltage range 100% load 170 ÷ 280 V Stabiliser AVR (Buck & Boost) Rated frequency 50 / 60 Hz (auto-detection) Frequency range ±5 Hz Auto~detection of frequency Yes Protection Fuse (800/1100) or resettable thermal cutoff (1500/2000/3000) Power factor 0.9 Rated voltage 208 / 220 / 230 / 240 V Voltage accuracy (battery mode) ±1.5% Power (VA/W) 800 / 720 Total harmonic distortion (THDv) < 2% linear load / < 5% non-linear load Waveform (battery mode) Pure sine wave Frequency 50/60 Hz (same as input) Frequency accuracy (battery mode) ±0.1Hz Admissible overloads in battery mode < 120% off at 1 min / < 150% off at 10 s Admissible overloads in-line mode < 120% off at 5 min / < 150% off at 10 s / >150 %: 1 s Socket type IEC No. Of sockets 8 Programmable sockets Yes, for critical / non-critical loads (4/4) Battery type Pb-Ca sealed, AGM, maintenance-free Charge type I/U (constant current/constant voltage) Recharge time 4 hours to 90% Battery test Automatic on every start + one x week Temperature voltage compensation Yes Ports RS-232/USB-HID Intelligent slot Slot for SNMP/potential-free contacts/ MODBUS Monitoring software For Windows, Linux and Mac Type LCD + keypad Values Voltage, power and input and output frequency / Battery voltage / % battery charge / % load / Operating mode / Fault / Discharge time / Mute Operating modes Normal / Stabilisation (AVR) / Battery / Fault Alarm Output battery mode, polarity, low battery (back up time), charger failure and overload Audible Every 10 s for battery operation. Every 2 s for low battery / Polarity. Every 1 s for overcharge. Continuous for fault. Failure Display LCD Cold start (start-up from batteries) Yes Emergency stop (EPO) Yes ADSL/fax/modem transient protector
YesGreen-function Yes, automatic stop in battery mode with load <5% Smart fan speed Yes, smart control of fan speed Site wiring fault Yes, error detection of phase-neutral rotation and/or absence of earth Operating temperature 0º C ÷ 40º C Relative humidity Up to 95%, non-condensing Maximum operating altitude 2,400 masl (power degradation up to 5,000 m) Acoustic noise at 1 meter < 45dB Safety EN IEC 62040-1 Electromagnetic compatibility (EMC) EN IEC 62040-2 (C2) Operation EN IEC 62040-3 Corporate certification ISO 9001, ISO 14001, ISO 45001 Depth (mm) 410 Width (mm) 438 Height (mm) 88 Weight (kg) 12.9
Description
This UPS is designed to deliver effective protection against power fluctuations, surges, and outages, safeguarding critical data and maintaining uninterrupted operations. Its line-interactive technology enhances power conditioning, while the sine-wave output ensures stable performance for sensitive electronic devices, making it an ideal choice for small to medium IT infrastructures and essential network systems.