My Techfocus

First time here? Sign Up


Salicru SPS 2000 ADV T B1 Line-interactive sine-wave Uninterruptible Power Systems (UPS) tower

  • NG # 00260-HW-SAL-060

Manufactured by:

This seller generally responds in under 48 hours

The Salicru SPS 2000 ADVANCE T B1 – 2000 VA Line-Interactive Sine-Wave Uninterruptible Power Supply (UPS) Tower is a high-capacity, reliable power protection system designed to safeguard computer rooms, servers, and critical IT infrastructure. Utilizing line-interactive technology with Automatic Voltage Regulation (AVR), it stabilizes voltage fluctuations while providing a pure sine-wave output, ensuring compatibility with sensitive and high-demand electronic devices.

Specification

TECHNOLOGYLine-interactive
FORMATTower
Rated voltage230 V
Voltage range 100% load165 ÷ 290 V
StabiliserAVR (Buck & Boost)
Rated frequency50 / 60 Hz (auto-detection)
Frequency range±5 Hz
Auto~detection of frequencyYes
ProtectionResettable breaker
Rated voltage230 V
Voltage accuracy (battery mode)±10%
Power (VA/W)2000 / 1800
Total harmonic distortion (THDv<5%
Waveform (battery mode)Pure sine wave
Frequency50/60 Hz (same as input)
Frequency accuracy (battery mode)±1 Hz
Compatibility with APFC loadsYes (1)
Performance Stabiliser mode (AVR)>92%
Performance Battery mode>80%
Admissible overloads in battery mode110% for 1 min / >130% immediate
Admissible overloads in-line mode110% 1min / 120% immediate
Socket typeIEC C13 
No. Of sockets6
Battery typeNot included, Pb-Ca sealed, AGM, maintenance-free
Charge typeI/U (constant current/constant voltage)
Recharge time4 hours to 90%
Battery testAutomatic on each start-up + manual
PortsRS-232 / USB (HID)
Intelligent slotSlot for SNMP/potential-free contacts/ MODBUS
Monitoring softwareFor Windows, Linux and Mac
TypeLCD + keypad
ValuesInput and output voltage / % load / % battery / backup
LevelsConnected load / overload / battery / low battery
Operating modesNormal / Stabilisation (AVR) / Battery / Fault
AlarmBattery / low battery / overload / failure
AudibleEvery 30 s for battery operation. Every 2 s for low battery / Polarity. Every 0,5 s for overcharge. Continuous for fault.
FailureDisplay LCD
Cold start (start-up from batteries)Yes
Emergency stop (EPO)Yes
Operating temperature0º C ÷ 40º C
Relative humidityUp to 95%, non-condensing
Maxium operating altitude2,400 masl
Acoustic noise at 1 metre<45 dB (2)
SafetyEN-IEC 62040-1
Electromagnetic compatibility (EMC)EN 62040-2
OperationEN 62040-3
Corporate cerificationISO 9001, ISO 14001, ISO 45001
Depth (mm)327
Width (mm)140
Height (mm)191
Weight (kg)12.2

Description

With a 2000 VA capacity, this UPS supports medium to large IT environments, networking devices, and professional workstations, delivering uninterrupted power to prevent data loss, downtime, and hardware damage. Its tower design enables easy placement in office or technical environments without complex installation, while advanced surge protection and intelligent battery management extend battery life and enhance equipment safety.