Salicru SPS 1500 ADV T B1 Line-interactive sine-wave Uninterruptible Power Systems (UPS) tower
-
NG # 00259-HW-SLA-059
Manufactured by:
The Salicru SPS 1500 ADVANCE T B1 – 1500 VA Line-Interactive Sine-Wave Uninterruptible Power Supply (UPS) Tower is engineered to deliver high-performance power backup and protection for critical IT systems, computer rooms, and professional workstations. Featuring line-interactive technology with Automatic Voltage Regulation (AVR), it ensures continuous stabilization against voltage fluctuations while providing a pure sine-wave output, making it suitable for sensitive and high-demand electronic equipment.
Specification
TECHNOLOGY Line-interactive FORMAT Tower Rated voltage 230 V Voltage range 100% load 165 ÷ 290 V Stabiliser AVR (Buck & Boost) Rated frequency 50 / 60 Hz (auto-detection) Frequency range ±5 Hz Auto~detection of frequency Yes Protection Resettable breaker Rated voltage 230 V Voltage accuracy (battery mode) ±10% Power (VA/W) 1500 / 1350 Total harmonic distortion (THDv <5% Waveform (battery mode) Pure sine wave Frequency 50/60 Hz (same as input) Frequency accuracy (battery mode) ±1 Hz Compatibility with APFC loads Yes (1) Performance Stabiliser mode (AVR) >92% Performance Battery mode >80% Admissible overloads in battery mode 110% for 1 min / >130% immediate Admissible overloads in-line mode 110% 1min / 120% immediate Socket type IEC C13 No. Of sockets 6 Battery type Not included, Pb-Ca sealed, AGM, maintenance-free Charge type I/U (constant current/constant voltage) Recharge time 4 hours to 90% Battery test Automatic on each start-up + manual Ports RS-232 / USB (HID) Intelligent slot Slot for SNMP/potential-free contacts/ MODBUS Monitoring software For Windows, Linux and Mac Type LCD + keypad Values Input and output voltage / % load / % battery / backup Levels Connected load / overload / battery / low battery Operating modes Normal / Stabilisation (AVR) / Battery / Fault Alarm Battery / low battery / overload / failure Audible Every 30 s for battery operation. Every 2 s for low battery / Polarity. Every 0,5 s for overcharge. Continuous for fault. Failure Display LCD Cold start (start-up from batteries) Yes Emergency stop (EPO) Yes Operating temperature 0º C ÷ 40º C Relative humidity Up to 95%, non-condensing Maxium operating altitude 2,400 masl Acoustic noise at 1 metre <45 dB (2) Safety EN-IEC 62040-1 Electromagnetic compatibility (EMC) EN 62040-2 Operation EN 62040-3 Corporate cerification ISO 9001, ISO 14001, ISO 45001 Depth (mm) 327 Width (mm) 140 Height (mm) 191 Weight (kg) 10.2
Description
With its 1500 VA capacity, this UPS offers enhanced load support, ideal for medium-sized IT environments, servers, and networking setups requiring uninterrupted power. Its tower format allows easy integration into office or data environments without complex installations, while its advanced surge protection and intelligent battery management extend the battery's life and protect connected devices from harmful power anomalies.