RKI GX-9000 Marine Gas Detector Series
TF:
002736-HW-RKI-036
Overview
The GX-9000 Marine Gas Monitor sets the new industry standard for rugged, reliable portable gas detection. It’s tough, water proof design utilized features based on years of gas detection design experience, to assure that the instrument will operate properly to protect workers and property in all kinds of harsh gas detection applications.
| Sampling method | Suction type/Double type |
| Principle of detection | New Ceramic catalytic Method, Thermal Conductivity Method, Non-Dispersive Infrared Method, Potentiostatic Electrolysis Method, Photo-Ionization Detector |
| Detection range | Depend on target gas. |
| Type of alarm | Gas alarm / fault alarm |
| Display of alarm | Lamp blinking / buzzer / gas concentration display blinking |
| Explosion protected construction | Flameproof enclosures + Intrinsic safety |
| Explosion-proof class | ATEX : Ⅱ1G Ex da ia ⅡC T4 Ga/Ⅱ1G Ex ia ⅡC T4 Ga IECEx : Ex da ia ⅡC T4 Ga/Ex ia ⅡC T4 Ga * Dry battery models when using Duracell (MN1500) batteries: -40 °C to +40 °C: T4, -40 °C to +60 °C: T3. |
| Ingress proof rating | IP66/68 |
| Approvals | Japan Ex, ATEX, IECEx, MED, EN 60079-29-1, EN 50104, JIS |
| CE marking | EMC / ATEX / RoHS / RE |
| Power source | Lithium ion battery unit [BUL-9000] or Dry battery unit (AA alkaline battery 6 pcs.) [BUD-9000] |
| Continuous operation | Approx. 25 hours (fully charged) [Lithium ion battery unit] Approx. 12 hours (25℃, no alarm, no lighting) [Dry battery unit] * Varies depending on the mounted sensor. |
| Dimensions | Approx. 6.2 (W) × 3.3 (H) × 5.2 (D) in. (158 (W) × 85 (H) × 132 (D) mm) |
| Weight | Approx. 38.8 oz. (1.1 kg) includes battery and battery unit |
| Operating temperature range | Temporary ambient conditions: -40 °F to +140 °F (-40 ℃ to +60 ℃) Continuous ambient conditions: -4 °F to +122 °F (-20 ℃ to +50 ℃) * May vary depending on the mounted sensor. |
| Operating humidity range | Temporary ambient conditions : 0 to 95 %RH (no condensation) Continuous ambient conditions :10 to 90 %RH (no condensation) * May vary depending on the mounted sensor. |
| Operating pressure range | 80 to 120 kPa (80 to 110 kPa for explosion-proof range) |
| Target gas | C2H2, CH4, CL2, CO, CO2, H2, H2S, HCL, i-C4H10, NH3, O2, O3, SO2, VOC |
GX-9000 is ideally suited to Harsh Environment applications requiring multi-gas detection
GX-9000 can detect up to 6 x different gas types simultaneously. This is an extremely versitile Gas Detector suitable for Marine / Onshore and Underground applications.