Endress+Hauser Electronic differential pressure Deltabar FMD71

Endress+Hauser Electronic differential pressure Deltabar FMD71

Endress+Hauser
TF: 007115-HW-ENDRESS-015
Overview

An advanced electronic differential pressure system using two ceramic sensor modules and a single transmitter to deliver highly accurate and stable level, volume, and mass measurements in pressurized liquid applications. It eliminates mechanical issues found in traditional DP systems, improving reliability and reducing maintenance.

Measuring principle

Differential pressure

Characteristic

Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.

Supply voltage

4...20 mA HART:
12...45V DC (Non Ex)
Ex ia: 12...30V DC

Reference Accuracy

0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor

Long term stability

0.05% of URL/year of individual sensor

Process temperature

–25...+150°C
(–13...+302°F)

Ambient temperature

–40...+80°C
(–40...+176°F)

Measuring cell

100 mbar...40 bar
(1.5 psi...600 psi)

Vacuum resistance

0 mbar

Max. Turn down

100 : 1

Max. overpressure limit

60 bar (900 psi)

Process connection

Threads
Flansch (DIN, ASME, JIS)

Process connection hygienic

DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent

Material process membrane

Ceramic
316L, AlloyC

Material gasket

Viton, Kalrez, EPDM, NBR, Silicone

Fill fluid

Silicone Oil

Material housing

Die-cast aluminum
Stainless steel

Communication

4...20 mA HART

Certificates / Approvals

ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex

Design approvals

NACE MR0175,
EN10204-3.1,

Hygienic approvals

EHEDG,
3A

The electronic DP Deltabar FMD71 uses high-purity ceramic sensors to digitally measure hydrostatic and head pressure, calculating level directly in the transmitter. With multivariable HART diagnostics, overload-resistant sensors, improved safety architecture, and low total ownership cost, it offers a modern, maintenance-free alternative to traditional differential pressure setups.